Re: TC-08 data logger providing values in channel without thermocouple

Hi Gary, I'm reminded of the fact that the TC-08 will show the ambient temperature from measurements of the cold junction temperature for the channel, inside the unit, as soon as the channel is enabled. So, if this is what you were referring to then there is no need to send the device in to us. Rega...
by Gerry
Fri Oct 08, 2021 2:17 pm
Forum: PicoLog
Topic: TC-08 data logger providing values in channel without thermocouple
Replies: 2
Views: 4715

Re: TC-08 data logger providing values in channel without thermocouple

Hi Gary,

Looks like you may have a faulty device, could you send your query into our helpdesk via support@picotech.com.

Regards,

Gerry
by Gerry
Fri Oct 08, 2021 2:13 pm
Forum: PicoScope 6 for Linux
Topic: Where is the math menu?
Replies: 1
Views: 4823

Re: Where is the math menu?

Hi jsiscart,

There are no Math Channels on PicoScope 6 for linux. These should be in PicoScope 7 for Linux.

Regards,

Gerry
by Gerry
Fri Oct 08, 2021 2:07 pm
Forum: Getting Started
Topic: calibration report for a TC-08 (after sale and delivery)
Replies: 1
Views: 2674

Re: calibration report for a TC-08 (after sale and delivery)

Hi Giuseppe,

We don't hang on to Calibration reports for sold products. If you want one then the thing to do is ask for one at the point of purchase.

Unfortunately, you would need to return the TC-08 to us for calibration, if you still need a Calibaration Certificate.

Regards,

Gerry
by Gerry
Fri Oct 08, 2021 2:01 pm
Forum: USB PC Oscilloscopes
Topic: Probe malfunction on 5444D
Replies: 1
Views: 2571

Re: Probe malfunction on 5444D

Hi Xelectro,

Could you send your issue in to our Helpdesk via support@picotech.com, so that we can issue you a returns number in order to get the probe returned and resolve the issue.

Regards,

Gerry
by Gerry
Fri Oct 08, 2021 1:49 pm
Forum: PicoScope 7 Early Access for Windows, Linux and Mac
Topic: "No Data Error" on Linux Mint, but how to get Picoscope 6?
Replies: 3
Views: 6649

Re: "No Data Error" on Linux Mint, but how to get Picoscope 6?

Hi the other Tom,

Assuming that you were using the beta for the Ubuntu distro, you can download from here: https://www.picotech.com/library/picosc ... -for-linux.

Regards,

Gerry
by Gerry
Fri Oct 08, 2021 1:36 pm
Forum: Applications
Topic: Use PicoScope as a Phase Locked Loop comparator and VCO?
Replies: 1
Views: 3942

Re: Use PicoScope as a Phase Locked Loop comparator and VCO?

Hi sheimend, You could adjust the Signal Frequency based upon your capture data, but the PicoScope would be more like a stepped VCO, as you would have to capture the data, (a time delay of a capture period) establish a USB connection (delay of anywhere between <10ms to 10's of ms) transfer the data ...
by Gerry
Fri Oct 08, 2021 1:16 pm
Forum: PicoLog
Topic: voltage leak change in data
Replies: 1
Views: 3689

Re: voltage leak change in data

Hi Damian, I apologise for the delay in responding to this. The TC-08 Terminal board/adapter already divides voltages down and has a voltage divider on the 5V connector which is a 100K resistor in series with a 1K resistor across the Channel input. So, what you need to do is just add another 100K re...
by Gerry
Fri Oct 08, 2021 10:00 am
Forum: Introductions
Topic: ARINC-429 serial protocol decoding
Replies: 1
Views: 7050

Re: ARINC-429 serial protocol decoding

Hi Damian, I apologise for the delay in responding to this. We don't as yet, have a repository for serial decoding link files. Did you have a link file to share, or were you just looking for one. This is currently being looked into, for a few of the available protocols, as to whether we will provide...
by Gerry
Thu Oct 07, 2021 4:14 pm
Forum: PicoScope 6 for Windows
Topic: Regarding the binary file capture from picoscope 6000
Replies: 1
Views: 3819

Re: Regarding the binary file capture from picoscope 6000

Hi maitry.raval, If you're referring to the file size being a problem, so that you only want to capture the raw data, then the .psdata file format is the smallest file that you will be able to create. If you're referring to capturing a Serial Communications Protocol, then your 6000 series PicoScope ...
by Gerry
Thu Oct 07, 2021 4:04 pm
Forum: USB PC Oscilloscopes
Topic: Setting or changing default setup parameters, series 5000.
Replies: 1
Views: 4544

Re: Setting or changing default setup parameters, series 5000.

Hi jacasey, If you mean that the data from a previous session created on the a laptop would be available on the same laptop, when they plug the PicoScope in, then yes, that is true. If, on the other hand, you mean that the user will be able to see the data from the previous session on a different la...
by Gerry
Thu Oct 07, 2021 3:07 pm
Forum: USB PC Oscilloscopes
Topic: 2206B PicoScope 6 persistence mode
Replies: 6
Views: 8226

Re: 2206B PicoScope 6 persistence mode

Hi Maks, This is not what I am seeing. Also, the Demo mode simulation is not a good comparison against using a real PicoScope, with all of the real world constraints associated with that. Could you create a Video of what you believe the issue is (if you use a tool such as ScreenToGif, you should be ...
by Gerry
Thu Oct 07, 2021 2:55 pm
Forum: Pre-Sales Advice
Topic: Which PicoScope 2000 for viewing before & after Dirty Electricity experiments
Replies: 1
Views: 5764

Re: Which PicoScope 2000 for viewing before & after Dirty Electricity experiments

Hi NPendrigh

We have an existing discussion on this topic, so I would suggest that you go here: topic37961.html?&p=144601&hilit=dirty+e ... ty#p144601.

Regards,

Gerry
by Gerry
Thu Oct 07, 2021 2:51 pm
Forum: Introductions
Topic: Alarm Timing
Replies: 2
Views: 7979

Re: Alarm Timing

High Mtak, In the SDK, you would just set the Digital Outputs in response to analyzing the data (for your PicoLog 6 alarm condition). So, the rate at which you could change the Digital Outputs would depend upon, the conversion time, the time to check if the data meets your alarm condition and then s...
by Gerry
Thu Oct 07, 2021 1:56 pm
Forum: Pre-Sales Advice
Topic: ADC24: does it support NPN pulse (rpm) logging?
Replies: 4
Views: 6033

Re: ADC24: does it support NPN pulse (rpm) logging?

Hi Sedex,

Yes that would work if you're given RPM, and if you use Excel to count edges. Glad you found your solution (just make sure that you're aware of limitations due to the ADC conversion times).

Just out of curiosity, what sort of spec are the mini PC's?

Regards,

Gerry